Plastic Water Pipe indies that the average flow velocity for normal flow is 6.7 ft/s ( 2 m/s) and for fire flow is 11.6 ft/s ( 3.5 m/s). The AWWA Water Distribution Operator Training Handbook suggests 5 ft/s (1.5 m/s) as a typical

Conveniently and easily check if the selected pipe wall thickness is adequate to safely contain the high pressure fluid by implementing ASME B31.3, AS 1210 and AS 4041 in a simple script. Determine the required ASME B16.5 flange rating byscript.

UPVC pressure pipes for Cold Potable Water Special UPVC Pressure Pipes for Cold Water Nominal Outside Diameter Wall Thickness (9 Bar) size Inch Min. mm

3 Dimensions & Pressure Ratings Pipe Type O.D. Size SDR LH PIP 91 80 PIP 51 100 PIP 41 125 PIP 32.5 CL 63 IPS 64 CL 100 IPS 41 SEWER PSM 35 CL 125 IPS 32.5 CL 160 IPS 26 CL 200 IPS 21 40 DWV IPS — 80 DWV IPS — SCH 40 IPS — SCH 80 IPS

PPR pipes & fittings Characteristics: 1. Well heat resistance ability The pipes can be used for a long time while the working temperature of water is 70 C. They can be used for a short time while it reaches 95 C. The softening temperature is 140 C. 2. Well insulation

MDPE Pipe Excellent pressure resistance, tested to 16 BAR. Comfortably exceeds the performance requirements of UK Water Byelaws Scheme. Tested and approved by various testing institutes worldwide. Water Regulations Advisory Scheme roved (WRAS

PVC Pipes Schedule 40 Friction loss and Velocity Diagrams Friction loss (psi/100 ft) and velocity for water flow in plastic PVC pipe schedule 40 Surge Water Hammer Rapidly closing or opening valves or starting stopping pumps may cause pressure transients in pipelines known as surge or water

Chloride) (PVC) Pressure Pipe (4" 12") for Water,” and certified to CSA B137.3 “Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure liions.” Blue Brute DR25 shall have a pressure class of 690 kPa (100 psi). DR18 pipe shall have a pressure class of 1,034

Schedule 80 2" PVC has a pressure rating of 400 psi at room temperature. Therefore, 2" schedule 80 PVC pipe is acceptable for this appliion. The total pressure at any time in a pressure type system (operating plus surge or water hammer) should not exceed

HDPE Pipe pressure classes that can be made between Pn4 Pn32 and the production of the desired diameter and size of HDPE pressure pipe system has undergone many tests in 1950, particularly in the carriage of drinking water.

Water pressure ratings at 23 o C (73 o F) for schedule 40 ABS (Acrylonitrile Butadiene Styrene) plastic pipes with material designation ABS 2112 ABS 1316 ABS 1210 ABS 1208 are indied in the diagram below. ABS Pipes Schedule 40 Pressure psi Pressure

Conveniently and easily check if the selected pipe wall thickness is adequate to safely contain the high pressure fluid by implementing ASME B31.3, AS 1210 and AS 4041 in a simple script. Determine the required ASME B16.5 flange rating byscript.

Pipe ID and wall thickness can vary from .2% up to 5%. Pipe ID will vary, even along a single piece of pipe. Metric Pipe is here and Metric Fittings Here ** Disclaimer: Pressure ratings above are for a temperature of 68 73F. See de rating chart below for higher

In the late 1960’s when the North China plastic pipe industry was in its infancy, the Hydrostatic Stress Board developed design factors that would assure reliable thermoplastic plastic pressure piping. For water piping, they first developed long term pressure

9 uPVC Pressure Pipe System Pressure Pipe System For Water Distribution Imperial Range BS 3505 Nominal Outside Wall Thickness Size Diameter CLASS C CLASS D CLASS E (9 Bar) (12 Bar) (15 Bar) Inch. Min. Max. Min.

E = instantaneous dynamic elastic modulus of pipe material, psi = 150,000 psi for HDPE per AWWA M55 The surge pressure, P S, caused by a sudden change in liquid flow velocity is: g a v P S Δ ( ) = (7) Where WL118 0207 Rev Feb 2007 Supersedes

WL Plastics PE3408 HDPE Pipe Determining Pressure Ratings

for a given pipe material establishes its hydrostatic design basis or HDB. The HDB is then utilized in either equation 1 3 or 1 4 to establish the pressure rating for a particular pipe profile by the appliion of a design factor (DF). The DF for water service is ,

Pipe Working Pressure Calculator, Tube Working Pressure Calculator, Tubing Working Pressure Calculator,HDPE Tube Working Pressure Calculator,HDPE Pipe Working Pressure Calculator Equation: P = (2*S*T)/(( *T)*SF) Where: P = Fluid Pressure (psi)

PVC I.P.S. Pressure Rated Pipe DR 41/DR 32.5/DR 26/DR 21/ DR 17 Pressure Rated 100, 125, 160, 200 and 250 psi Ring Tite Joint 1.5" 12" For Use In Rural, Agricultural Water Systems and Other Services. Puhui HDPE pipeline’s (Puhui HDPE pipeline) I.P.S. Pressure PVC Pipe conforms to ASTM D 2241 for standard dimension ratios and is available in SDR 41 (100 psi), SDR 32.5 (125 psi), SDR 26 (160 psi), SDR 21

WSAA TN 4 Design of Pressure Pipeline Systems for Water Supply Using PVC M and PVC O Pipes new Clause—see below). the maximum A available at (d) Using Table 3.2 determine the fatigue de rating factor F to be applied. (e) Calculate MCPR as detailed

Working Pressure Rating and Fatigue Life. S 3 (2013) PPI PACE software Working Pressure Rating and Fatigue Life Fatigue of Plastic Water Pipe: A Technical Review with Recommendations for PE4710 Pipe Design Fatigue (Oliphant, ASCE Pipelines 2012)

Standard Test Method for Pressure Rating Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40 and 80 Socket Type. F2263 14() Standard Test Method for Evaluating the Oxidative Resistance of Polyethylene (PE) Pipe to Chlorinated Water